Contents
Lab equipment rentals made simple and affordableAboutContact
EzuRentals

Renting an Agilent 34980A Data Acquisition Unit

What to know before renting an Agilent 34980A switch/measure unit: plug-in modules, relay life, calibration, typical rental terms and cost ranges.

By Daniel WhitmorePublished 4 min read

The Agilent 34980A is a modular switch/measure mainframe that many labs rent when a test campaign needs more channels than a bench DMM can offer. Instead of buying eight plug-in cards you may need for three months, you rent the chassis with the modules your application actually uses.

This guide covers what the 34980A does well, which plug-in modules drive the rental price, how relay wear and calibration affect a rental, and what to check on delivery. Figures below are typical ranges, not quotes — confirm specifics with your rental provider before signing.

What the 34980A Actually Does

The 34980A is an 8-slot mainframe with a built-in 6.5-digit DMM (optional on some configurations) and a switching backplane that connects any slot to the internal measurement bus. You populate it with multiplexer, matrix, RF, or digital I/O modules depending on whether you are scanning thermocouples, switching 4-wire resistance, or routing signals to an external instrument.

Throughput is the reason people choose it over a stack of separate switches. A typical multiplexer scan runs on the order of 100 to 250 channels per second depending on range and integration time, and the internal DMM settles quickly enough that full-rack scanning jobs finish in minutes rather than hours.

Mechanically it is a 3U half-rack unit that fits a standard 19-inch rack with the optional rack-mount kit. Front-panel terminals give quick access to the internal DMM, so the unit can double as a bench meter when you are not scanning.

  • 8 plug-in slots, 3U half-rack footprint
  • Optional internal 6.5-digit DMM
  • Scan rates roughly 100–250 channels/s on multiplexer cards
  • Supported interfaces: GPIB, LAN, USB
65034921A mux100034922A mux115034932A matrix130034941A RF mux85034950A digital I/O
Indicative monthly rental cost by module type (midpoint of range) (USD per month)

Choosing the Right Plug-in Modules

The chassis is rarely the cost driver — the modules are. A 20-channel armature multiplexer (34921A) is the workhorse for general scanning and is usually the cheapest card to rent. A 4x8 or 8x16 reed matrix (34932A, 34933A) costs more because it packs more relays and is used for automated test switching.

For thermocouple work, specify a card with an internal thermocouple reference junction (the 34921A and 34922A families include one). For low-level signals, look at the low-thermal-EMF variants rather than assuming a standard mux will hold microvolt accuracy.

RF switching (34941A/34942A) and digital I/O cards (34950A) are niche and often have longer lead times from rental fleets, so reserve them early. Tell your provider the channel count, signal type, voltage and frequency — that single message prevents most mismatched shipments.

  • 34921A: 20-ch armature mux, general scanning, thermocouple reference
  • 34922A: 40-ch armature mux for higher channel counts
  • 34932A/34933A: reed matrices for automated switching
  • 34941A/34942A: RF multiplexers, 50 Ω, check bandwidth
  • 34950A: digital I/O when you need to drive relays or read logic

Relay Life and Wear on Rented Units

Every multiplexer card carries a finite relay life, typically 1 to 10 million mechanical operations for armature relays and much higher for reed types, but the contact rating falls as you approach switching of inductive or high-voltage loads. A rented card may already have years of scan time behind it.

Ask the provider for the relay closure count on the specific modules being shipped, not just the chassis serial number. A 34921A with 80% of its rated cycles consumed is still usable for low-voltage thermocouple scanning but is a poor choice for switching 250 V loads.

If your campaign involves thousands of relay operations per hour, consider keeping spare cards on site or negotiating a swap clause. Relay failure shows up as intermittent open channels or elevated contact resistance — both are easy to misdiagnose as wiring faults when you are mid-test.

Calibration, Verification and Traceability

Rent the mainframe with a current calibration certificate that covers the internal DMM, and confirm the certificate lists the measurement ranges you will use. A unit calibrated on the 10 V range six months ago tells you little about its 100 mV accuracy today unless the certificate includes that range and the associated uncertainty.

For switching-only jobs, module contact resistance matters more than DMM accuracy. A simple verification with a known resistor across a few channels catches most relay problems before you commit to a long scan. Follow the same discipline you would apply to any rented instrument: prepare your lab for the arrival and log the verification results.

If the rental runs longer than six months, ask whether recalibration mid-term is included. Many providers cover it; some charge for the shipping and downtime. Our general notes on calibration and maintenance for rented equipment explain what to put in writing.

Typical monthly rental ranges for 34980A configurations (indicative, USD)
ConfigurationModules IncludedTypical Monthly RangeBest For
Chassis + 1 mux34921A (20-ch)$400–$900Thermocouple and general voltage scanning
Chassis + 2 mux2 × 34922A (40-ch)$700–$1,300Higher channel-count environmental tests
Chassis + matrix34932A 4x8 reed matrix$800–$1,500Automated switching in ATE setups
Chassis + RF mux34941A 50 Ω$900–$1,700RF signal routing up to a few GHz
Chassis + digital I/O34950A$600–$1,100Relay driving and logic capture

Interfaces, Software and Setup Time

The 34980A supports GPIB, LAN and USB, but the LAN option is what most modern test benches use. Confirm the firmware revision and that the web interface loads — older firmware can be fussy with current browsers, and you do not want to discover that on day one of a campaign.

Budget half a day for rack installation, cable dressing and a trial scan before trusting results. The rear terminal blocks accept bare wire or optional screw-terminal connectors; if you are scanning many thermocouples, order the connector kits with the rental rather than improvising.

For lab-wide planning, the same checklist applies as for any bench instrument: see the step-by-step rental checklist and how to choose a rental period so the unit arrives when your harness is ready, not a week early.

What a 34980A Rental Costs

Expect a mainframe with one multiplexer card to rent in the range of roughly $400–$900 per month, with longer terms reducing the effective monthly rate by 20–40%. Each additional module typically adds $80–$250 per month depending on type; reed matrices and RF cards sit at the top of that range.

Deposits vary widely. Some providers waive them for established accounts; others hold one to two months' rental value. Shipping both ways and insurance are sometimes bundled and sometimes line items, so compare total cost rather than the headline monthly figure.

If your project is measurement-heavy rather than switching-heavy, compare against renting a chromatography system or a balance before committing budget — see the chromatography rental cost guide and balance rental pricing for context on how instrument rentals are usually structured.

Key points

  • The modules, not the chassis, drive rental cost — specify channel count and signal type up front.
  • Ask for relay closure counts on the exact cards being shipped before you accept them.
  • Confirm the calibration certificate covers the DMM ranges you will actually measure.
  • Budget half a day for racking, wiring and a trial scan before trusting data.
Daniel Whitmore

Editor

Daniel has spent years helping laboratories source and manage scientific instruments through rental programs. He focuses on making equipment costs and contract terms easier to understand for research and quality teams. His writing covers practical rental planning, calibration, and lab logistics.

Related articles

Cookie Preferences

Required for the site to function, such as remembering your cookie choice.

Not used on this site.

Not used on this site.